<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-01 22-24-37
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 40 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 65 kHz 4420 0,1584
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,4 dBr 5,41 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 65 kHz MIN: 12 kHz % above 76 kHz: 0,1584 Acquired: 2026/05/01 22.23.33 Total samples: 4420 Equivalent time: 0:03:41 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 6,1 dBr MIN: 4,4 dBr AVE: 5,41 dBr % above 12,2 dBr: 0,0 Last value: 5,7 dBr (2026/05/01 22.23.32) 22.10 22.12 22.14 22.16 22.18 22.20 22.22 0 2 4 6 Pm [dBr]